Services - Calibration and Measurement

Category 0 Laboratory Calibration
As well as calibrating the reference standards that are to be sent to customers with a new instrument, we also offer calibration of used items. This way, you can actually improve measuring capability by quantifying the errors in reference standards. These errors can then be taken into account and reduce your uncertainty of measurement.

UKAS (NAMAS) Accredited Capability

Calibration
Precision measurement of a 3 line calibration glass

The Talyrond 73 UHPR is the most accurate
roundness instrument available
Calibration

Roundess

The glass hemisphere is a high precision standard used to both calibrate and evaluate the performance of roundness measuring instruments.

By using exclusive measuring techniques, the UKAS (NAMAS) laboratory calibrates the hemisphere to a resolution of 1 nanometre, with an uncertainty of measurement of 5 nanometres.

The resulting certificate includes a polar plot of the profile of the measured plane, which allows the user to accurately ascertain any departures from roundness by comparing the calibrated plot against that obtained on their Talyrond system.

Calibration

Straightness

Assessment of the accuracy of a straightness and cylindricity measuring instrument can be verified by means of a precision cylinder, which will have been calibrated using a mechanical reversal technique such that the pure error in the straightness of the cylinder is plotted . The result obtained on the users system can then be compared the calibrated profile on the UKAS (NAMAS) certificate.

For more details, contact Pat Kilbane on +44 (0) 116 246 3104 or e-mail calibration@taylor-hobson.com

Calibration

Surface Texture

The UKAS (NAMAS) laboratory is able to measure all of the parameters associated with surface texture, including German and French derivatives.

Roughness standards are calibrated to an uncertainty of Ra which is the lowest currently available from any laboratory accredited by UKAS.

A tungsten carbide sphere is used to calibrate the Form Talysurf Series range of instruments. It's radius, roundness/sphericity and surface texture are each calibrated to provide a high precision multi-purpose standard.

The ball may be used to calibrate the instrument, or as a "confidence gauge", to ensure its accuracy is maintained.

Calibration

Diameter and Length

The laboratory is currently accredited for the calibration of spheres, plugs, rings, and length bars. Temperature corrected measuring techniques are used in conjunction with sophisticated control software to achieve uncertainties down to ± 0.5mm

Calibration

Polygons and Prisms

The basic methods employed for angle measurement are either the accurate division of a circle, by using a high precision index table, or the generation of a known angle by means of a precision sine bar (angle generator) or indexing head (rotary table) .

The precision index table is used in conjunction with an autocollimator for the calibration of a polygon. Any errors found in the polygon are tabulated on the UKAS (NAMAS) certificate. By taking these errors into account during its use, a higher accuracy of measurement can be achieved.

Calibration

Autocollimators

A small angle generator jointly designed by Taylor Hobson and NPL is used in conjunction with traceably calibrated gauge blocks for the calibration of an autocollimator. Both progressive and periodic errors are measured and certified. Knowledge of these errors enables more precise use of the instrument by the operator.

Calibration

Clinometers and Levels

Block levels, clinometers and electronic levels are calibrated by use of sophisticated sine lever techniques. For example, a Talyvel 4 electronic level is calibrated using a Taylor Hobson small angle generator. The user benefits from the ability to compensate for known errors when using the instrument.

Telescopes

The line of sight and displacement errors of a Micro Alignment Telescope are assessed by viewing into fixed focus and variable focus collimators . Deviations are recorded on the UKAS (NAMAS) certificate, providing the means for more accurate measurement. Micrometer and focussing accuracies are also verified using traceably calibrated scales and artifacts.


Calibration
Calibration
scanning white light interferometry | scanning broadband | scanning broadband interferometry | interferometry | optical metrology tool | non contact measurement | 3 dimensional measurement | optical microscope | non destructive measurement | interferometers | white light measurement | SWLI | SBI | MEMS measurement instrument | micro roughness measurement | step height measurement | phase interferometer | autocollimators | Micro Alignment Telescope | Surface Finish Metrology | Metrology Solutions | Metrology uk | Metrology solutions uk | Metrology solutions usa | Metrology usa | bearing metrology | calibration | taylor hobson talysurf | metrology gauge manufacturers | surface texture | length measuring instruments | alignment telescope | Links